How to find the cause of equipment vibration: a methodology, not a list of causes

A fan starts humming after the impeller gets cleaned. You hold a sensor against it, see 7 mm/s, and stop there: you have a number, not a cause. A list of possible causes does not help much here, because almost every one of them can raise the same number. What helps is a working order that rules out theories one at a time.

Updated 27 August 2026 · by AXILINE · Vila Nova de Gaia

In short: The cause is found not from a single spectrum (the breakdown of vibration by frequency) but from the whole set of signs together: context (what changed and when it started), how reliable the reading is, the ratio of vibration across all bearing supports in three directions, how the frequencies relate to running speed, the shape of the time waveform, repeatability, and phase — the angle showing at what point in the turn the vibration reaches its peak. You gather this data first, then formulate a single hypothesis, and test it with one controlled action. The diagnosis is not made by the instrument — it comes from the combination of the signs, the machine's behaviour, and a confirming check.

Step 1. Gather context before you even open the instrument case

Half the diagnosis lives in the maintenance log and the operator's memory. The instrument answers the question "how much." Context answers the question "why."

Vibration that appeared the same day a bearing was replaced, and vibration that built up over three months, call for different theories. The first points to the installation. The second points to wear, build-up, or a settling foundation.

After cleaning the impeller, a machine can hum for two reasons at once: the build-up was removed unevenly and created unbalance, and the housing mounting got shaken loose in the process. Context narrows the field of theories, but it does not replace the measurement.

Step 2. Make sure the reading reflects the machine, not your mounting

Before you explain a number, check whether you can trust it. False readings account for nearly half of all "mysterious" cases, and people then spend weeks chasing these artefacts as if they were a real defect.

How the sensor is mounted sets the frequency band you can actually see anything in. A hand-held probe cuts off everything above roughly 500–1000 Hz. A magnet on a clean, flat pad covers a wider band. A stud gives you the widest band and the best repeatability. A magnet sitting on a layer of paint or on rust turns into a spring with a resonance of its own.

On the Balanset-1A, RMS vibration-velocity measurement runs in the 5–200 Hz band, while the ISO 20816 zones are written for the 10–1000 Hz band. Keep this in mind: this kind of reading will not show the high-frequency bearing content — that gets found separately, through acceleration and the envelope spectrum, a method that isolates weak bearing impacts.

Step 3. Take a baseline map: every support, three directions

One point is not a diagnosis. Go over every bearing support in three directions: horizontal (H), vertical (V) and axial (A). Label them the standard way: 1H, 1V, 1A, 2H and so on, numbering the supports from the drive end. A two-channel instrument takes two points at once and saves you half the runs.

The diagnostic information is not in the absolute figure but in the ratio between directions. Here is how to read this map.

H is roughly equal to V, axial is small

The classic picture of unbalance. The rotor drags the support around in a circle, so the radial directions come out comparable. Axial stays small, except on overhung rotors and wheels with face run-out.

H is 3–5 times larger than V

A pronounced directionality. This is how a resonance of the support or frame in one direction, or loose mounting, tends to behave. Unbalance on its own does not usually produce a skew like this.

V is larger than H

A rare and very telling picture. Look at the fixing to the foundation: a soft foot (a support that does not sit flush against the frame and twists the casing when the bolt is tightened), a cracked foot, soft grout, loose bolts. On a properly mounted machine, vertical stiffness is higher than horizontal, and if V has pulled ahead, that stiffness is gone.

Axial is comparable to radial

Look for shaft misalignment, especially the angular kind, as well as a bent shaft, a tilted bearing, or a problem with the thrust assembly. Balancing will not help here: it only brings down radial 1x.

One support is loud, the neighbouring one is quiet

The cause is local: that specific bearing assembly, its mounting, or a resonance belonging to that one support. Rotor unbalance is almost always visible at both supports.

Take the whole map under one operating condition and log it in a table right away, along with the speed, the load and the support temperatures. Two hours later, you will not remember what flow rate you took point 2A at.

Step 4. Convert hertz into multiples of running speed

The spectrum shows hertz. Diagnostics lives in multiples. Divide the peak's frequency by the running-speed frequency and you get an order: 1x, 2x, 0.5x, 3.7x. The order itself names the class of cause.

It is a one-line calculation. 1480 RPM is 1480/60 = 24.67 Hz. A peak at 49.3 Hz gives exactly 2.00x. A peak at 100 Hz at the same speed gives 4.05x, and that is not a harmonic at all — it is twice the mains frequency. The difference matters: one gets fixed by mechanics, the other by electricians.

On a drive with a VFD and a floating speed, an ordinary spectrum smears the lines. There, the approach is order analysis: the axis is referenced to a once-per-turn mark, so the running-speed components stay put regardless of speed. How the spectrum itself works is covered in a separate article on reading a vibration spectrum.

Step 5. Open the time waveform, check repeatability and phase

A spectrum averages, and so it hides one-off events. An early-stage bearing fault produces an impact once every few shaft turns. In the spectrum, that impact smears into the noise; in the time waveform, you see the individual pulses. Look at both, always.

Record for at least 4–6 shaft turns. At 1500 RPM that is 0.2 s, in practice people record 1–2 s. On a slow-turning roll at 60 RPM you need about 6 s, or a rare event simply will not land in the sample.

Phase on its own does not show you where the heavy point sits. What it shows is a difference: between directions, between supports, between runs. It is the difference that does the work.

Step 6. Bring the signs together into a hypothesis using the table

Dominant frequencyDirection and behaviourHypothesisCheck
1x, clean spectrumH roughly equal to V, axial small, phase stable, amplitude grows roughly as the square of speedRotor unbalanceA trial weight of known mass at a known radius. A valid trial run changes 1x by 20–30% or phase by 20–30°
1x, clean spectrumA sharp peak over a narrow speed range, vibration drops past the peak, phase shifts by around 180°Resonance of the support, frame or rotorA controlled start-up and coast-down with 1x amplitude and phase recorded. A bump test on the stopped machine
1x and 2x are comparableAxial has risen noticeably, 1x phase across the coupling differs by around 180°Shaft misalignmentCheck for a soft foot first, then align the shafts with dial indicators or a laser system on the warmed-up machine
A comb of 1x, 2x, 3x plus 0.5x and 1.5xPronounced directionality, phase does not repeat from run to runLoose mounting or rubbingTorque to sequence with a check measurement after each foot. Looseness will give itself away as a jump in the number at a specific bolt
Twice the mains frequency, 100 Hz on a 50 Hz supplyRadial, weak dependence on mechanical loadAn electromagnetic cause: air-gap eccentricity, a loose statorCut the power during coast-down. The 100 Hz line cuts off instantly; the mechanical one decays smoothly along with the speed
High frequencies, not multiples of running speed, blurred, noise floor risingLocalised at one support, that support's temperature is higher than its neighbour'sRolling-element bearing defectsAn acceleration envelope spectrum in the 2–10 kHz band, a repeat measurement in a week, a look at the lubrication
A subsynchronous line at 0.4–0.5xA machine on sleeve bearings, the line is unstable in frequencyOil-film instability, oil whirlCase-mounted sensors will not work here. You need proximity probes (non-contact shaft-position sensors) and the orbits built from them. Check the oil's viscosity, temperature and pressure
Blade-pass frequency and broadband noise at 1–10 kHzGrows when moving away from the operating point, sounds like "gravel in a pipe"Cavitation or flow separationBring the operating condition back to the design point, raise the inlet head. The cause is process-related, not the rotor
Two close lines, the vibration pulses audiblyPulsing with a period of around a second, both lines stableBeating between two independent sources, for example two fans on a shared ductStop the second machine. The pulsing will disappear; the machine is fine

The table gives you a hypothesis, not a conclusion. The same picture can come from two different causes, and the reverse is also true: looseness can raise 1x, and shaft misalignment can add harmonics. It is the right-hand column that turns a hypothesis into a diagnosis.

Sources: ISO 13373-3:2015 · ISO 13373-5:2020

Step 7. Change one parameter at a time and watch the response

This is where you stop observing and start experimenting. There is one rule: change exactly one thing per run. Otherwise the number changes, and you will never know what the change actually belongs to.

  1. 01

    Speed

    On a VFD, sweep the range in steps of 5–10% and record 1x and phase at each step. Unbalance builds up smoothly, roughly as the square of speed. Resonance produces a narrow peak and a phase shift. A natural frequency of the structure stays put in hertz while the running-speed line moves past it.

  2. 02

    Load

    Hold the speed steady, change the flow or the feed rate. Hydraulics and aerodynamics respond immediately. Unbalance is almost indifferent to load. Shaft misalignment often grows with load because of how the coupling reacts.

  3. 03

    Temperature

    Take a reading on a cold machine and again after 40–60 minutes of running. A drift in vibration during warm-up points either to thermal growth and induced misalignment, or to thermal bow in the rotor. A machine like this gets aligned with pre-set cold offsets, not aligned to zero.

  4. 04

    Power supply

    Disconnect the motor from the supply and watch the suspect line at the moment of coast-down. The electromagnetic component cuts off instantly; the mechanical one decays along with the speed. The test costs nothing and gives an unambiguous answer.

  5. 05

    Mounting

    Torque the bolts to a sequence and measure after each one. This finds you the specific foot, rather than "looseness in general." The order matters: fasteners and soft foot first, then shaft alignment, and only after that, balancing.

Log everything in a single table: speed, load, support temperature, overall vibration (the total level across all frequencies), 1x, 2x, phase. Half a day of work, and this table becomes your finding.

Three alarm levels, and why the trend matters more than one figure

A single measurement tells you the condition. Two measurements taken apart in time tell you the trend, and it is the trend that drives the decision. A machine that has sat at 4.0 mm/s for three months is less of a worry than one that climbed from 1.5 to 3.0 in a month, even though the second one is formally "better."

That is why setpoints are not set as a single threshold but as three levels. That way you get time to prepare, instead of an emergency shutdown on the night shift.

Warning

Note it and watch more closely. You stop nothing, just add a point to the chart and shorten the interval between readings. A working guideline is the boundary between zones B and C in the applicable part of ISO 20816, or a statistical threshold built from that machine's own history.

Alarm

Investigate and plan an intervention. You look for the cause using the sequence described above, and get parts and a maintenance window ready. The ISO 20816 guideline is the boundary between zones C and D, but for a specific machine it is more honest to work from its own baseline.

Shutdown

Shut down per the site's own procedure. This level gets justified separately and agreed with operations, because a false shutdown costs money too.

Treat the zone A, B, C, D figures as working guidance, and check the applicable part and edition of the standard for your specific machine: power, speed, support type and exceptions by machine type are all set out separately there. We cover the three different "tolerances" in a separate article.

Sources: ISO 20816-1:2016 · ISO 13373-3:2015

One hypothesis, one check, and the honest limits of the method

State a single hypothesis in the machine's own terms, not the instrument's. Not "high 1x," but "impeller unbalance after uneven cleaning." Then pick the one action that tells this theory apart from the closest competing one, and do only that.

You do not diagnose from a single spectrum, and that is a property of the method, not excess caution. A spectrum shows the average frequency content and does not tell cause from effect. Loose mounting raises 1x and pretends to be unbalance. A soft foot twists the casing and creates a genuine misalignment, which you will honestly find and honestly correct — and it will come back within a week. Resonance amplifies any excitation, so under resonance almost everything looks like unbalance.

There are also things case-mounted sensors simply cannot see. The shaft's position in the clearance and oil-film instability need proximity probes and orbits. Early bearing defects need acceleration and an envelope spectrum up to 10 kHz. Broken rotor bars in a motor need fine frequency resolution plus stator current analysis. If your problem falls into one of these, you need a different instrument and a different specialist — not one more trial weight.

What AXILINE does when the picture does not add up

We come to your site and go through this whole route: a reading at every bearing support in three directions, overall vibration and 1x with phase, an FFT spectrum and the time waveform on two channels at once, and a check for resonance from a start-up and coast-down. If the picture points to unbalance, we balance in one or two correction planes right in the machine's own bearings, with no disassembly and no removing the rotor. If it does not, you get a clear finding on what to do instead of balancing, and you do not pay for weights that would not have helped.

You can also buy the instrument and work with it yourself. The Balanset-1A kit is two accelerometers, a laser phase sensor, a two-channel USB module with preamplifiers, integrators and an ADC, and Windows software. The 1x vibration-velocity measurement range is 0.02–80 mm/s, speed from 100 to 100,000 RPM, phase measurement error ±1°. The software displays overall vibration and 1x, the spectrum and the time waveform, keeps an archive, and calculates the tolerance against the G grades (balance quality grades). You build the trend from your own saved data, not from memory.

Consultation support comes from engineers who design and manufacture the Balanset instruments and use them for on-site balancing themselves. Send us your readings, spectra and a description of the machine, and we will work through them with you.

Sources: Balanset-1A manufacturer specification · Balanset-1A operation manual

Frequently asked questions

Where do I start if a fan starts humming right after the impeller is cleaned?

Not with weights. Start with context: exactly what was done to the wheel and the housing. Then take a reading at both bearing supports in three directions and compare overall vibration with 1x. If 1x accounts for most of the overall figure, the spectrum is clean, H and V are comparable, and axial is small, that is unbalance from build-up removed unevenly. If a comb of harmonics and axial vibration have risen, check the housing and foot mounting you touched during cleaning first.

Can you find the cause of vibration from a single spectrum?

No. A spectrum shows the average frequency content and does not tell cause from effect. Loose mounting raises 1x and looks like unbalance, resonance amplifies any excitation, and a soft foot creates a genuine misalignment that will come back after you fix it. The minimum set for a diagnosis is the spectrum plus the time waveform plus phase plus the ratio between directions at every support plus the response to changing one parameter.

Why measure three directions if horizontal is usually enough?

Because the diagnostic value is in the ratio, not the figure. Axial vibration comparable to radial turns you away from balancing and toward shaft alignment and checking for a bent shaft. Vertical higher than horizontal means the fixing to the foundation has lost stiffness. Horizontal 3–5 times higher than vertical means resonance or looseness in one direction. From a single horizontal reading, these three cases all look the same.

How do I convert a peak from hertz into a multiple of running speed?

Divide the peak's frequency by the running-speed frequency in hertz. Running-speed frequency equals RPM divided by 60. At 1480 RPM that is 24.67 Hz, so a peak at 49.3 Hz gives 2.00x, while a peak at 100 Hz gives 4.05x and turns out to be twice the mains frequency, not a harmonic. Whole orders point to running-speed phenomena, half-orders to looseness and rubbing, fractional orders to bearings and belts.

What setpoints should I use if there is no measurement history for the machine?

Start with the guideline from the applicable part of ISO 20816: take the B/C zone boundary as a warning, the C/D boundary as an alarm, and agree the shutdown level separately with operations. In parallel, take a baseline on a sound, warmed-up machine, and after 3–5 rounds recalculate the thresholds from it statistically. After that, the standard's figures stay in the background, and the decisions get made by that specific machine's own trend.

What do I do if the signs point to two causes at once?

That is a normal situation, not a dead end. Fix things in order of dependency: whatever distorts everything else comes first. Fasteners and soft foot, then shaft alignment, then balancing. Take a check measurement after every step and record it. If the second cause shrinks on its own once you fix the first, it was a consequence, not a separate defect.

Related content

Preparing equipment for on-site balancing: a customer checklist

Prepare five things: sound mechanical condition, a clean impeller, physical access to the bearing housings and correction planes, an agreed window for 3–6 runs with stops, and someone authorized to start the machine. Add the nameplate speed, power, rotor mass, type of supports, and photos of the assembly, so the engineer arrives with the right fasteners and can calculate the tolerance right away. Balancing does not substitute for repair: if a bearing is worn out, the feet aren't bolted down, or the rotor is rubbing against the housing, fix that first, then balance.

Open page

How to reduce equipment vibration: a sequence that saves money

Measure first, repair second. Take the vibration reading at the bearing housings in mm/s RMS over the 10-1000 Hz band and compare the overall level (all vibration as one number) with the 1x running-speed component — the part of the vibration at rotation frequency that imbalance creates. If 1x accounts for most of the level, on-site rotor balancing will bring the vibration down. If not, the cause is loose fasteners, shaft misalignment, bearings, or resonance, and weights on the wheel won't help.

Open page

Balancing production-line equipment at the point of operation

Yes, we balance production-equipment rotors on site. Three conditions are needed: the rotor starts up at running speed and holds it steadily, there's access to the bearing supports for sensors and to a correction plane for weights, and the once-per-turn component 1x — vibration at the rotor's rotation frequency, which is exactly what unbalance creates — accounts for most of the vibration. If 1x is small and the machine still shakes, the cause is in the fixings, misalignment, the bearings or resonance, and we'll say so before any work starts. In food, pharmaceutical and chemical production we work without hot work: bolted stainless-steel weights and studs, or removing metal by drilling in allowed locations.

Open page

Describe your equipment and the problem

We'll answer your questions, clarify the details, and let you know what's needed for an estimate and a visit.

Submit a Request WhatsApp Pricing